The NSN part number 5925-01-252-7779 manufactured by Boeing Company The, Sensata Technologies Inc is available in NSN Components’ inventory. Owned and operated by ASAP Semiconductor, we have an inventory of over six billion parts, including NSN Parts 000-8006-189, 203-1-1-62-502-1-1. ASAP is dedicated to streamlining the parts procurement process for our customers, with dedicated account managers ready to solve procurement issues that they face. Each NSN 5925-01-252-7779 part of Circuit Breaker we ship goes through numerous quality checks and inspections, to ensure we sell only the highest-quality parts. Ready to start? Then submit a Request for Quote from this page today.
Alternative NSN: 5925-01-252-7779 |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012527779 |
NCB Code: USA (01) |
Manufacturers: Boeing Company The, Sensata Technologies Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
000-8006-189 | boeing company the | circuit breaker | Avl | RFQ |
203-1-1-62-502-1-1 | sensata technologies inc | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.920 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.770 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.125 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
FREQ | FREQUENCY IN HERTZ | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 1.300 OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |
Warrantied inventory at competitive prices
Search the world's largest inventory of electronic components by manufacturer, category or part number
All inventory ready to ship from our sellers
We sell only warrantied and traceable parts
Don’t forget That If You Need a Quote for A Part, You Can Get One Within Fifteen Minutes By Filling Out Or Instant RFQ form On the Homepage of This Website.
Request for Quote